← OrreryThe Ecliptic is an Orrery publication

Cover Story · Star Power desk

Fusion's One-Cent Diode, Fifteen Years On

The price target for the diodes that pump fusion lasers is about one US cent per peak watt, where it stood in 2011. Published prices are 10 to 130 times higher, and volume plus more powerful bars closes that gap only from the bottom of the range. Efficiency and lifetime, which set a plant's output and running cost, are further from specification than the price debate suggests.

USD 0.01 / W
about one US cent: the price target per peak watt of pump light in 2026 sources, against USD 0.007 in the 2011 Lawrence Livermore report: no real change in fifteen years
10–130×
how far published current prices, USD 0.10 to 1.30 per peak watt, sit above that target
40–80 GW
peak pump power one plant needs: USD 4bn to 104bn of diodes at published current prices, USD 0.4bn to 0.8bn at target (Star Power estimates)
19–48×
price reduction from a 100-fold rise in volume and a threefold rise in power per bar on the 2011 report's scaling (Star Power estimate)

The price

The target stood still because the order never came

0.010.101.00USD per peak watt, log scale (each gridline is ten times the last)Target, 2011 report0.007Target, 2026 sourcesabout 0.01Modelled one-plant build, 20110.018–0.033Current, bars (FBH)0.10Current, QCW bars (Holonomy)0.30–1.30
Published targets and prices for fusion pump diodes per peak watt, plotted on a log scale so that equal distances are equal ratios. Dots are single published values; bars are published ranges. TRUMPF's figure of about EUR 1 per watt for stacks is not shown because euro figures are not converted. Sources: the 2011 Lawrence Livermore report, FBH and Holonomy Systems, as reported in Star Power TRP-0033. Not illustrative.

In January 2011 a Lawrence Livermore report co-written with authors from 14 diode companies set a target of USD 0.007 per peak watt. In 2026 the Ferdinand-Braun-Institut (FBH), Fraunhofer ILT and Leonardo Electronics put it at about USD 0.01.

  • Current prices: USD 0.10 per watt for commercial bars (FBH), USD 0.30 to 1.30 for high-power QCW bars (Holonomy Systems) and about EUR 1 for diode stacks (TRUMPF). Bars and stacks are different products, and Holonomy sells a rival device.
  • The bill for one plant: 40 to 80 GW of peak pump power costs USD 4bn to 104bn at published current prices and USD 0.4bn to 0.8bn at target (Star Power estimates).
  • Modelled, never bought: five vendor cost studies in the 2011 report priced a one-time build for one plant at USD 0.018 to 0.033 per watt with 500 W bars. Today's prices are 3 to 72 times that (Star Power estimate).
  • Scale of the precedent: HAPLS, the largest working diode-pumped example in the report, is pumped by 3.2 MW of diodes. A plant needs 40 to 80 GW.

The levers

Volume and bar power reach the target only from the low end

Both levers together19–48×1×10×100×Reduction needed to reach USD 0.01 per watt, log scaleFrom USD 0.10 per watt10×From USD 0.30 per watt30×From USD 1.30 per watt130×
Reduction needed to reach USD 0.01 per peak watt from each published current price, against the 19- to 48-fold reduction available from both levers (shaded band). Log scale. The band is a Star Power estimate that applies the 2011 report's scaling exponents of 0.4 to 0.6 to today's prices and assumes the two levers are independent. Source: Star Power TRP-0033.

The industry cites two levers. On the 2011 report's scaling exponents a 100-fold rise in production lowers price 6 to 16 times, and raising power per bar from 500 W to 1.5 kW adds a factor of three. Together they give 19 to 48 times (Star Power estimate).

  • Where that reaches from: USD 0.01 per watt is reachable from a starting price of up to USD 0.19 to 0.48 per watt.
  • From USD 0.10: a 10-fold reduction is needed, which the two levers cover with margin.
  • From USD 1.30: a 130-fold reduction is needed, and a further 2.7 to 6.8 times has to come from somewhere else.
  • A caution on the exponents: at a 20% price fall per doubling of output, the same 100-fold step gives only about 4.4 times (Star Power estimate).

The specification

Efficiency and lifetime are further from target than price

Efficiency at 1 kW per bar50%60%70%80%Measured62–64%Target70–72%Lifetime, gigashots05101520Demonstratedmore than 2Targets5 to 20Navy: demonstrated. Teal: target.
Demonstrated values against targets. Efficiency is for bars at 1 kW, on an axis that starts at 50%, not zero; lifetime is on a linear axis from zero. The lifetime result is for single emitters, not bars. Sources: ams-OSRAM prototypes as reported by TRUMPF, FBH single-emitter tests and published targets, as reported in Star Power TRP-0033. Not illustrative.

Price per watt falls when each bar delivers more power. Efficiency and lifetime are lost at the same step, and no published device found by Star Power meets two of the three targets at once at the 880 nm wavelengths the neodymium and ytterbium designs use.

  • Efficiency: ams-OSRAM prototype bars at 1 kW measure 62% at 880 nm and 64% at 940 nm, against a target of 72% in 2011 and 70% now. FBH states that 70% or more is possible today only at about 0.5 kW per bar.
  • What the shortfall is worth: 71 to 89 MWe in Inertia Enterprises' 290 MWe baseline plant case. This is a Star Power estimate and assumes that case was built on 72% diodes, which Inertia has not stated.
  • Lifetime: in FBH's test three of five single emitters passed 2 gigashots, against targets of 5 to 20. At a 5-gigashot life a 30-year plant would need roughly two sets of diodes (Star Power estimate).
  • Our reading (Star Power): a diode at two cents and 72% would be a better purchase than one at one cent and 62%.
The Ecliptic, Issue No. 018, cover analysis, drawn from Star Power TRP-0033 (November 13, 2026). Prices, targets and device results are as published by the sources TRP-0033 cites; plant bills, lever reductions and the efficiency penalty are Star Power estimates. Interpretation is Star Power's.
THE ECLIPTICan Orrery publication
Content is produced by AI systems with human editorial oversight.